4 Repair
4.17 Replacement of Connected Services box
Continued
7
Refitting DSQC 680
Use this procedure to refit the Connected Services box, version DSQC 680.
1
2
3
4
5
6
7
Continues on next page
182
Action
Pull the latch (A) to the left, and push the Connected
Services box out.
Note
For controllers produced before August 2019 with DSQC 680 to be replaced by
DSQC1016/1023, contact your local ABB for assistance.
For controllers produced after August 2019, use the following procedure.
Action
DANGER
Before any work inside the cabinet, read the safety information in section
safety on page
32.
ELECTROSTATIC DISCHARGE (ESD)
The unit is sensitive to ESD. Before handling the unit read the safety information in
section
The unit is sensitive to ESD on page
Pull the latch to the left and push the Connected Services box in position on the
mounting bracket.
Refit the safety board unit and secure it with attachment screws.
Reconnect all connectors to the Connected Services box, Ethernet switch and safety
board.
Refit the cabinet cover.
Perform the function tests in section
features work properly.
© Copyright 2009-2020 ABB. All rights reserved.
Information
A
xx1400001460
49.
Function tests on page 121