2 Installation and commissioning
2.11.1 Installation of external operator's panel
Continued
9
10
11
12
13
14
15
102
Action
Cover the holes for Motor on button and
Mode switch on the controller with a
blanking plug.
Connect the earth cable to the ground ter-
minal inside the cabinet.
Connect the signal connectors Ext.A21.X6
and Ext.A21.X9 to the connector X6 and X9
on the safety board.
Strap the cables and secure the attach-
ments screws for contactor unit and safety
board unit.
Fit the external operator's panel harness to
the wall cabinet with four attachment
screws.
Connect the connectors and earth cable
inside the wall cabinet.
Mount the front panel of the external oper-
ator's panel on the wall cabinet with four
attachment screws.
© Copyright 2009-2020 ABB. All rights reserved.
Info/illustration
xx1400002803
A: ground terminal
Product manual - IRC5 Compact
3HAC047138-001 Revision: M
A