2 Installation and commissioning
2.11.4 Installing the Safety module DSQC1015 for SafeMove
Continued
Item
G
Installing the Safety module
1
2
3
4
5
6
Continues on next page
108
Equipment
Harness extended Key switch
Standard toolkit
Circuit diagram
Action
DANGER
Before any work inside the cabinet, read
the safety information in section
safety on page
32.
ELECTROSTATIC DISCHARGE
(ESD)
The unit is sensitive to ESD. Before hand-
ling the unit read the safety information in
section
The unit is sensitive to ESD on
page
49.
Remove the cover of the cabinet.
Remove the computer unit.
Open the computer unit by removing the
attachment screws and lift off the cover.
Disconnect the fan connector.
CAUTION
Be careful with the fan cable when opening
and removing the upper cover. The fan
cable must not be stretched.
Remove the attachment screw on top of
the slot bracket.
© Copyright 2009-2020 ABB. All rights reserved.
Note
3HAC057075-001
Used when the controller has the option
735-3 or 735-4 Additional contacts.
The contents are defined in section
ard toolkit, IRC5 on page
See
Circuit diagrams on page
Note/Illustration
Electrical
See
Removing the controller cover on
page
88.
See
Replacement of computer unit on
page
139.
xx1300000684
A Attachment screws (4 pcs.)
B Cover
Product manual - IRC5 Compact
Stand-
209.
221.
A
B
3HAC047138-001 Revision: M