4 Repair
4.2 Replacement of safety board
Continued
8
9
Refitting
Use the following procedure to refit the safety board.
1
2
3
4
5
6
7
8
132
Action
Remove the eight attachment screws.
Gently lift the safety board out.
Note
Always grip the board around the edges to avoid damage to the board or its
components.
Action
DANGER
Before any work inside the cabinet, read the safety information in section
safety on page
32.
WARNING
The unit is sensitive to ESD. Before handling the unit, see
on page
49.
Gently lift the safety board out of the ESD safe bag and fit it into position on the safety
board plate.
Secure the safety board with its attachment screws.
Refit the safety board unit protection cover.
Reconnect all connectors.
Refit the cabinet cover.
Perform the function tests in section
features work properly.
© Copyright 2009-2020 ABB. All rights reserved.
Note/illustration
xx1400001380
The unit is sensitive to ESD
Function tests on page 121
Product manual - IRC5 Compact