ABB IRC5 Compact Product Manual page 150

Hide thumbs Also See for IRC5 Compact:
Table of Contents

Advertisement

4 Repair
4.7 Replacement of Safety module DSQC1015 for SafeMove
Continued
Refitting the Safety module
1
2
3
4
5
6
7
Continues on next page
150
Action
DANGER
Before any work inside the cabinet, read
the safety information in section
safety on page
32.
ELECTROSTATIC DISCHARGE
(ESD)
The unit is sensitive to ESD. Before hand-
ling the unit read the safety information in
section
The unit is sensitive to ESD on
page
49.
Fit the Safety module in position by push-
ing it into the socket on the motherboard.
Refit the attachment screw on top of the
Safety module bracket.
Refit the fan connector and close the com-
puter unit.
CAUTION
Be careful with the fan cable when closing
the cover. The fan cable must not be
squeezed.
Refit the computer unit.
Refit the cover of the cabinet.
© Copyright 2009-2020 ABB. All rights reserved.
Note/Illustration
Electrical
xx1500001761
A Attachment screw
B Safety module
CAUTION
Always grip the board around the edges to
avoid damage to the board or its compon-
ents.
xx1300000684
A Attachment screws (4 pcs.)
B Cover
See
Replacement of computer unit on
page
139.
Product manual - IRC5 Compact
A
B
A
B
3HAC047138-001 Revision: M

Hide quick links: