Field Service Ver3.0 Nov.2006
(2) Procedure for reinstallation
[3]
[1]
[7]
[2]
[5]
[6]
[4]
[3]
[3]
1050fs2084c
1.
Move the V-mirror unit [1] toward the V-mirror
positioning hole [2].
2.
Insert the optics unit positioning jig [3] into the V-
mirror positioning hole [2] and fix the V-mirror unit
[1].
NOTE
• Be sure to insert the optics unit positioning jig
[3] from the front side and pass it through the
V-mirror unit [1].
• Be care full not to confuse the V-mirror posi-
tioning hole [2] with the unused hole [4].
3.
Insert the optics unit positioning jig [6] into the
exposure unit positioning hole [5].
4.
Press the exposure unit [7] against the optics unit
positioning unit [2].
5.
Reinstall the exposure unit with 4 screws.
6.
Remove 2 optics unit positioning jigs.
7.
For the parts to be installed hereafter, reinstall
them following the removal steps in reverse.
6. OTHERS