5. FIRMWARE VERSION UP
(2) When using the USB cables
Preparations are made of the following when a connection is made.
• PC into which transferred files (rewritten data) have been copied.
• UBS cables
1)
Procedure
Step
1
Turn OFF the power of the copier.
2
Turn OFF the power of the PC.
3
Remove 5 screws and then remove the upper right cover.
4
Connect the USB port and the PC with the cables.
5
Connect the USB cables of the PC to the ISW connectors.
NOTE
• When exiting the ISW, be sure to clean each mirror of the scanner.
218
Operations
Field Service Ver3.0 Nov.2006