3. PERIODIC CHECK
[2]
[1]
[1]
68
[3]
[1]
1050fs2014c
[2]
[2]
1050fs2015c
Field Service Ver3.0 Nov.2006
18.
Remove the toner supply sleeves /1 [1].
19.
Push the coupling in the arrow-marked direction
[2] and remove the toner supply sleeve /2 [3].
NOTE
• Be sure to reinstall the toner supply sleeves /1
[1] and /2 [2] in the direction as shown in the
drawing.
20.
Reinstall the above parts following the removal
steps in reverse.
NOTE
• After completion of disassembly/assembly of
the toner supply unit, be sure to select the
code 54-09 (rotation of the toner pump motor
(M28) and the air pump motor (M29)) in the I/O
check mode of the service mode and then
press the start button.
When toner drops off into the mixing section
due to the vibration of the disassembly/
assembly, this may cause the codes SC23-14
and SC23-17. (See chapter III "4.6.1 G.
Removing toner from the toner mixing sec-
tion" in the Field Service for the main body.)

Advertisement