3. PERIODIC CHECK
[3]
[5]
[8]
[9]
[6]
[2]
154
[2]
[6]
[7]
[1]
[4]
[5]
1050fs2165c
Field Service Ver3.0 Nov.2006
4.
Set the shaft [2] on the unused side of the new
cleaning web [1] to the driven couplings /Rr [3]
and /Fr [4].
NOTE
• Be sure to set each detent [5] on the driven
couplings to the notch [6] of the shaft on the
unused side. When the web is installed in the
wrong direction, it does not coincide with the
notch.
5.
Hold either side [8] of the shaft [7] on the take-up
side of the new cleaning web with both hands,
and take up the new cleaning web until the blue
line [9] disappears.
NOTE
• The performance of the new cleaning web is
guaranteed from the position in which the
blue line disappears. Be sure to take up the
cleaning web up to this position.