6. OTHERS
I.
Removing/reinstalling the upper cover /Rt
NOTE
• The same removal and reinstallation procedure is applicable when the DF-603 is provided.
(1) Procedure
[3]
[2]
J. Removing/reinstalling the original glass
NOTE
• The same removal and reinstallation procedure is applicable when the DF-603 is provided.
• When reinstalling the original glass, be sure that the shading correction plate (white) is on the
upper side of the glass.
(1) Procedure
[3]
[4]
[1]
[2]
[7]
256
1.
Remove 3 screw caps [1].
2.
Remove 5 screws [2] and then remove the upper
[2]
cover /Rt [3].
3.
Reinstall the above parts following the removal
steps in reverse.
[1]
1050fs2066c
1.
Remove the upper cover /Rt.
[6]
(See P.256)
2.
Remove 2 screws [1] and then remove the origi-
[5]
nal stopper plate /Lt [2].
3.
Remove 3 screws [3] and then remove the origi-
nal stopper plate /Rr [4].
4.
Remove 2 screws [5] and then remove the origi-
nal stopper plate /Rt [6].
5.
Remove the original glass [7].
6.
Reinstall the above parts following the removal
steps in reverse.
1050fs2067c
Field Service Ver3.0 Nov.2006