10. SPECIAL ADJUSTMENT FUNCTIONS

10.5.3 Parameters

When using the gain changing function, always set "
the manual mode of the gain adjustment modes. The gain changing function cannot be used in the auto
tuning mode.
Parameter
Abbrev-
No.
iation
7
PG1
Position control gain 1
36
VG1
Speed control gain 1
Ratio of load inertia moment to
34
GD2
servo motor inertia moment
35
PG2
Position control gain 2
37
VG2
Speed control gain 2
38
VIC
Speed integral compensation
Ratio of load inertia moment to
64
GD2B
servo motor inertia moment 2
Position control gain 2 changing
65
PG2B
ratio
Speed control gain 2 changing
66
VG2B
ratio
Speed integral compensation
67
VICB
changing ratio
68
CDP
Gain changing selection
69
CDS
Gain changing condition
70
CDT
Gain changing time constant
Name
Unit
rad/s
rad/s
0.1
times
rad/s
rad/s
ms
0.1
times
%
%
%
kpps
pulse
r/min
ms
10 - 6
4
" in parameter No.3 (auto tuning) to choose
Description
Position and speed gains of a model used to set the response
level to a command. Always valid.
Control parameters before changing
Used to set the ratio of load inertia moment to servo motor
inertia moment after changing.
Used to set the ratio (%) of the after-changing position
control gain 2 to position control gain 2.
Used to set the ratio (%) of the after-changing speed control
gain 2 to speed control gain 2.
Used to set the ratio (%) of the after-changing speed integral
compensation to speed integral compensation.
Used to select the changing condition.
Used to set the changing condition values.
You can set the filter time constant for a gain change at
changing.