1. FUNCTIONS AND CONFIGURATION

1.7 Servo system with auxiliary equipment

WARNING
(1) MR-J2S-100CP-S084 or less
(a) For 3-phase 200V to 230VAC or 1-phase 230VAC
(Note2)
3-phase 200V
to 230VAC power
supply or
1-phase 230VAC
power supply
No-fuse breaker
(NFB) or fuse
Magnetic
contactor
(MC)
Power
factor
improving
reactor
(FR-BAL)
To CN2
L
L
L
Control circuit terminal block
L
21
L
11
Regenerative brake
option
Note: 1. The HC-SFS, HC-RFS, HC-UFS 2000r/min series have cannon connectors.
2. A 1-phase 230VAC power supply may be used with the servo amplifier of MR-J2S-70CP-S084 or less. Connect the power
supply to L
and L
1
To prevent an electric shock, always connect the protective earth (PE) terminal
(terminal marked
) of the servo amplifier to the protective earth (PE) of the control
box.
Options and auxiliary equipment
No-fuse breaker
Magnetic contactor
Servo configuration software
Servo amplifier
MITSUBISHI
CHARGE
1
2
U
V
3
D
P
C
terminals and leave L
open.
2
3
Reference
Options and auxiliary equipment
Section 15.2.2
Regenerative brake option
Section 15.2.2
Cables
Chapter 7
Power factor improving reactor Section 15.2.3
CC-Link unit
MR-J2S-T01
CN10
To CN1A
To CN40
W
Protective earth (PE) terminal
1 - 21
CC-Link
Command device
Junction
terminal block
To CN1B
To CN3
To CN30
Personal
computer
(Note1)
Encoder cable
(Note1)
Power supply lead
Reference
Section 15.1.1
Section 15.2.1
Servo configuration
software
MRZJW3-SETUP152
Servo motor