3. CC-Link COMMUNICATION FUNCTIONS

3.5.6 Setting the CN1A CN1B external input signals

Using parameter No. 116 to 118, you can assign the input signals as the CN1A CN1B external input
signals. The signals assigned as the CN1A CN1B external input signals cannot be used in CC-Link.
Refer to Section 4.3.2 (1)(a) for the pins to which signals can be assigned.
In the initial status, the forward rotation stroke end, reverse rotation stroke end and proximity dog are
preset to be usable as the CN1B external input signals.
Parameter No.116
Parameter No.117
Parameter No.118
0
0
0
0
0
Signal name
Servo-on
Reset
Signal name
Forward rotation stroke end
Reverse rotation stroke end
Forward rotation start
Reverse rotation start
Signal name
Automatic/manual selection
Proximity dog
BIN 0: Used in CC-Link
BIN 1: Used as CN1A and CN1B external input signal
Signal name
Internal torque limit selection
Proportion control
Temporary stop/Restart
Signal name
Gain changing selection
BIN 0: Used in CC-Link
BIN 1: Used as CN1A and CN1B external input signal
Signal name
Point table No. selection 1
Point table No. selection 2
Point table No. selection 3
Point table No. selection 4
Signal name
Point table No. selection 5
BIN 0: Used in CC-Link
BIN 1: Used as CN1A and CN1B external input signal
3 - 33
Initial value
BIN
HEX
0
0
0
0
0
Initial value
BIN
HEX
1
1
3
0
0
Initial value
BIN
HEX
0
1
2
0
0
Initial value
HEX
BIN
0
0
0
0
0
Initial value
BIN
HEX
1
1
0
0
0
Initial value
HEX
BIN
0
0
0
0
0
Initial value
BIN
HEX
0
0
0
0
0