9. GENERAL GAIN ADJUSTMENT

9. GENERAL GAIN ADJUSTMENT

9.1 Different adjustment methods

9.1.1 Adjustment on a single servo amplifier

The gain adjustment in this section can be made on a single servo amplifier. For gain adjustment, first
execute auto tuning mode 1. If you are not satisfied with the results, execute auto tuning mode 2, manual
mode 1 and manual mode 2 in this order.
(1) Gain adjustment mode explanation
Gain adjustment mode
Auto tuning mode 1
(initial value)
Auto tuning mode 2
Manual mode 1
Manual mode 2
Interpolation mode
Parameter No. 2
Estimation of load inertia
setting
moment ratio
010
Always estimated
020
030
Fixed to parameter No.
34 value
040
000
Always estimated
Automatically set
parameters
PG1 (parameter No. 7)
GD2 (parameter No. 34)
PG2 (parameter No. 35)
VG1 (parameter No. 36)
VG2 (parameter No. 37)
VIC (parameter No. 38)
PG1 (parameter No. 7)
PG2 (parameter No. 35)
VG1 (parameter No. 36)
VG2 (parameter No. 37)
VIC (parameter No. 38)
PG2 (parameter No. 35)
VG1 (parameter No. 36)
GD2 (parameter No. 34)
PG2 (parameter No. 35)
VG2 (parameter No. 37)
VIC (parameter No. 38)
9 - 1
Manually set parameters
Response level setting of
parameter No. 3
GD2 (parameter No. 34)
Response level setting of
parameter No. 3
PG1 (parameter No. 7)
GD2 (parameter No. 34)
VG2 (parameter No. 37)
VIC (parameter No. 38)
PG1 (parameter No. 7)
GD2 (parameter No. 34)
PG2 (parameter No. 35)
VG1 (parameter No. 36)
VG2 (parameter No. 37)
VIC (parameter No. 38)
PG1 (parameter No. 7)
VG1 (parameter No. 36)

Hide quick links: