1. FUNCTIONS AND CONFIGURATION

1.6.2 Part name of CC-Link unit

MR-J2S-T01
C
N
1
0
R
S
W
1
2
3
1
2
S
W
C
N
3
0
C
N
4
0
Name/Application
CC-Link connector (CN10)
Wire the CC-Link cable.
Station number switches (RSW1, RSW2)
Set the station number of the servo amplifier.
RSW1: Set the ten place.
RSW2: Set the one place.
Baudrate switch (RSW3)
Select the CC-Link communication baudrate.
Occupied station count switch (SW1)
Set the number of occupied stations.
Name plate
Servo amplifier connector
Connect with the CN3 connector of the MR-J2S-CP-S084
servo amplifier.
Communication alarm display section
Indicates alarms in CC-Link communication.
L.ERR
SD
L.RUN
RD
S.ERR
WD
Personal computer connector (CN40)
Connect the personal computer.
Charge lamp
Lit when the control circuit is powered on.
Green: Normal
Orange: Watchdog