3. CC-Link COMMUNICATION FUNCTIONS
3.4 Servo amplifier setting
(1) Servo amplifier side operation modes
The MR-J2S- CP-S084 servo amplifier has the following operation modes:
Operation mode
Test operation mode
CC-Link operation mode
(2) Operation mode changing
(a) Operation mode changing conditions
Change the operation mode after making sure that:
1) The servo motor is at a stop.
2) The forward rotation start (RYn1) or reverse rotation start (RYn2) is OFF.
(b) Operation mode changing method
When changing from test operation to CC-Link operation, deselect test operation by switching
power OFF/ON.
CC-Link
operation mode
Symbol
A
B
The buttons in the operation section of the servo amplifier are operated to run the servo
motor.
CC-Link communication functions are used to operate the servo with the PLC programs.
Change with parameter unit
Changing
CC-Link operation mode
Test operation mode
Test operation mode
CC-Link operation mode
3 - 8
Description
A
B
Select the test operation mode with the button in
the operation section of the servo amplifier.
Deselect test operation mode by switching power
OFF/ON.
Test operation mode
Description