5. OPERATION

5. OPERATION

5.1 When switching power on for the first time

5.1.1 Pre-operation checks

Before starting operation, check the following:
(1) Wiring
(a) A correct power supply is connected to the power input terminals (L
amplifier.
(b) The servo motor power supply terminals (U, V, W) of the servo amplifier match in phase with the
power input terminals (U, V, W) of the servo motor.
(c) The servo motor power supply terminals (U, V, W) of the servo amplifier are not shorted to the
power input terminals (L
(d) The earth terminal of the servo motor is connected to the PE terminal of the servo amplifier.
(e) Note the following when using the regenerative brake option, brake unit or power regeneration
converter:
1) For the MR-J2S-350CP-S084 or less, the lead has been removed from across D-P of the control
circuit terminal block, and twisted cables are used for its wiring.
2) For the MR-J2S-500CP-S084 or more, the lead has been removed from across P-C of the servo
amplifier built-in regenerative brake resistor, and twisted cables are used for its wiring.
(f) When stroke end limit switches are used, the signals across LSP-SG and LSN-SG are on during
operation.
(g) 24VDC or higher voltages are not applied to the pins of connectors CN1A and CN1B.
(h) SD and SG of connectors CN1A and CN1B are not shorted.
(i) The wiring cables are free from excessive force.
(2) Environment
Signal cables and power cables are not shorted by wire offcuts, metallic dust or the like.
(3) Machine
(a) The screws in the servo motor installation part and shaft-to-machine connection are tight.
(b) The servo motor and the machine connected with the servo motor can be operated.
POINT
In the shipment status, Forward rotation stroke end (LSP), Reverse rotation
stroke end (LSN) and Proximity dog (DOG) are valid as the CN1A/CN1B
external input signals. However, this chapter explains them with the register
No. of the remote input.
, L
, L
) of the servo motor.
1
2
3
5 - 1
, L
, L
, L
, L
) of the servo
1
2
3
11
21

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents