3. CC-Link COMMUNICATION FUNCTIONS
Code No.
9100H
Auxiliary function data EEP-ROM command of point
to
table
911FH
Writes the auxiliary function data of point table No. 0
to 31 to EEP-ROM. Written to EEP-ROM, these
values are held if power is switched off.
The decimal value converted from the 2 lower digits of
the code No. corresponds to the speed block No.

3.5.5 Answer codes (RWrn+2)

If any of the monitor codes, instruction codes, position command data/point table Nos., speed command
data/point table Nos. set to the remote register is outside the setting range, the corresponding error code
is set to Answer code (RWwn+2). "0000" is set if they are normal.
Code No.
0
Normal answer
Code error
1
Parameter point table
2
selection error
Write range error
3
Item
Error related to Monitor code 1/Monitor code 2
Error related to Instruction code/Writing data
Error related to Position instruction data/Point table No.
Error related to Speed instruction data/Point table No.
Error
Instruction was completed normally.
The monitor code not in the specifications was set.
Read/write of the point table of No. 32 or later was set.
The parameter No. disabled for reference was set.
An attempt was made to write the parameter or point table data
outside the setting range.
3 - 32
Writing data (RWwn+3) contents
(PLC
Servo amplifier)
Convert the values into hexadecimal before making
setting.
Details