3. CC-Link COMMUNICATION FUNCTIONS
3.7 Function-by-function programming examples
This section explains specific programming examples for servo operation, monitor, parameter read and
write, and others on the basis of the equipment makeup shown in Section 3.7.1.
3.7.1 System configuration example
As shown below, the CC-Link system master local unit is loaded to run two servo amplifiers (1 station
occupied).
PLC
Power
CPU
supply
Master station
Input module
(X/Y00 to 1F)
(X20 to X2F)
Station No. 1
Servo amplifier
(1 station occupied)
3 - 41
Station No. 2
Servo amplifier
(1 station occupied)