(1) Setting of 5 or less-digit value
The following example provides the after-power-on operation procedure to set "1" in the auxiliary
function of point table No.1:
(Note)
Note. The example assumes that the status display screen that appears at power-on has been
set to the servo motor speed in parameter No. 18.
Press "UP" or "DOWN" after completion of the setting to return to the setting item screen. Further,
press "UP" and "DOWN" together to return to the point table No. display screen.
During flickering, press "MODE" for 2[s] to discard the new value and display the old value.
Press MODE three times.
··········The point table No. appears.
Press UP or DOWN to choose point table No. 1.
Press SET once.
Press UP five times.
Press SET twice.
··········The setting of the specified point table No. flickers.
Press UP once.
··········The setting can be changed during flickering.
Use UP or DOWN to change the setting.
Press SET to enter the value.