Servo Amplifier Terminal Block (Te2) Wiring Method - Mitsubishi Electric MELSERVO-J2-Super Series Instruction Manual

Servo amplifier
Hide thumbs Also See for MELSERVO-J2-Super Series:
Table of Contents

Advertisement

4. SIGNALS AND WIRING

4.11 Servo amplifier terminal block (TE2) wiring method

1) Termination of the cables
Solid wire: After the sheath has been stripped, the cable can be used as it is. (Cable size: 0.2 to
2.5mm
Twisted wire: Use the cable after stripping the sheath and twisting the core. At this time, take
Cable size
[mm
1.25
1.5
2
2.5
2) Connection
Insert the core of the cable into the opening and tighten the screw with a flat-blade screwdriver
so that the cable does not come off. (Tightening torque: 0.3 to 0.4N m (2.7 to 3.5Ib in)) Before
inserting the cable into the opening, make sure that the screw of the terminal is fully loose.
When using a cable of 1.5mm
2
)
care to avoid a short caused by the loose wires of the core and the adjacent pole.
Do not solder the core as it may cause a contact fault. (Cable size: 0.2 to 2.5mm
Alternatively, a bar terminal may be used to put the wires together.
2
] AWG
For 1 cable
BT1.25-9-1
16
TUB-1.25
16
AI1.5-8BK
BT2-9-1
14
TUB-2
AI2.5-8BU
14
AI2.5-8BK-1000
2
or less, two cables may be inserted into one opening.
To loosen.
To tighten.
Control circuit terminal block
Approx. 10mm
(0.39inch)
Bar terminal type
For 2 cables
AI-TWIN2
1.5-8BK
AI-TWIN2
1.5-12BK
AI-TWIN2
2.5-10BU
AI-TWIN2
2.5-13BU
Flat-blade screwdriver
Tip thickness 0.4 to 0.6mm (0.016 to 0.024in.)
Overall width 2.5 to 3.5mm (0.098 to 0.138in.)
Cable
Opening
4 - 29
Crimping tool
NH1
NICHIFU
YHT-2210
JST
CRIMPFOX-UD6
Phoenix Contact
NH1
NICHIFU
YHT-2210
JST
CRIMPFOX-UD6
Phoenix Contact
2
)
Maker

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents