3. CC-Link COMMUNICATION FUNCTIONS
(2) Writing the parameter
Change parameter No. 13 (JOG speed) of the servo amplifier of station 2 to "100".
Code No.
H830D
Set data
K100
The answer code at instruction code execution is set to D2.
Read setting
Description
Parameter No. 13 write (hexadecimal)
Description
Set data (decimal)
3 - 47
Reads remote input (RX20 to RX5F)
of buffer memory to M200 to M263.
Writes parameter No. 13 write (H830D)
to RW
and data (K100) to RW
W6
Turns on instruction code execution
demand (RY29).
Reads RW
to D2 when instruction code
R6
execution completion (RX29) turns on.
Turns off instruction code execution
demand (RY29).
Writes M100 to M163 to remote output
(RY20 to RY5F) of buffer memory.
.
W7

Hide quick links: