3. CC-Link COMMUNICATION FUNCTIONS
Code No.
8300
Data EEP-ROM instruction of parameter 0 to 124
to
Writes the values set in parameter No. 0 to 124 to
837CH
EEP-ROM. Written to EEP-ROM, these values are
held if power is switched off.
The decimal value converted from the 2 lower digits of
the code No. corresponds to the parameter No.
An error code is returned if an instruction code
outside the range set in parameter No. 19 or a value
outside the setting range of the corresponding
parameter is written.
8400H
Position data RAM command of point table
to
Writes the position data of point table No. 0 to 31 to
841FH
RAM. These values are cleared when power is
switched off.
8500H
A set of the upper and under bits makes position data.
to
When changing the data, always set the data of both
851FH
under and upper bits in order of under 16-bit data and
upper 16-bit data.
8400 to 841F: Position data in under 16 bits of point
table No. 1 to 31
8500 to 851F: Position data in upper 16 bits of point
table No. 1 to 31
Example
Instruction code 8413: Under 16 bits of point table No.
19
Instruction code 8513: Upper 16 bits of point table No.
19
8600H
Motor speed of point table
to
Writes the motor speeds of point table No. 0 to 31 to
861FH
RAM. These values are cleared when power is
switched off.
The decimal value converted from the 2 lower digits of
the code No. corresponds to the position block No.
8700H
Acceleration time constant data RAM command of
to
point table
871FH
Writes the acceleration time constants of point table
No. 0 to 31 to RAM. These values are cleared when
power is switched off.
The decimal value converted from the 2 lower digits of
the code No. corresponds to the position block No.
8801H
Deceleration time constant data RAM command of
to
point table
881FH
Writes the deceleration time constants of point table
No. 0 to 31 to RAM. These values are cleared when
power is switched off.
The decimal value converted from the 2 lower digits of
the code No. corresponds to the speed block No.
Item
3 - 30
Writing data (RWwn+3) contents
(PLC
Servo amplifier)
Convert the decimal values into hexadecimal before
making setting.
Convert the values into hexadecimal before making
setting.
Convert the values into hexadecimal before making
setting.
Convert the values into hexadecimal before making
setting.
Convert the values into hexadecimal before making
setting.

Hide quick links: