7. SERVO CONFIGURATION SOFTWARE
When the above choices are made, the following window appears:
a)
b)
(1) Servo motor speed setting ( a) )
Enter a new value into the "Motor speed" input field and press the enter key.
(2) Acceleration/deceleration time constant setting ( b) )
Enter a new value into the "Accel/decel time" input field and press the enter key.
(3) Servo motor start ( c), d) )
Hold down the "Forward" button to rotate the servo motor in the forward rotation direction.
Hold down the "Reverse" button to rotate the servo motor in the reverse rotation direction.
(4) Servo motor stop ( e) )
Release the "Forward" or "Reverse" button to stop the rotation of the servo motor.
(5) Jog operation window closing ( f) )
Click the "Close" button to cancel the jog operation mode and close the window.
(6) Cancel of jog operation
To cancel jog operation, switch off the power of the servo amplifier.