7. SERVO CONFIGURATION SOFTWARE
7.7.2 Positioning operation
Click the "Forward" or "Reverse" button to start and rotate the servo motor by the preset moving distance
and then stop.
Click "Test" on the menu bar and click "Positioning" on the menu.
Clicking displays the following window.
Since this window shows the precaution for use of the MR-J2S-B, click the "OK" button.
POINT
In the positioning operation mode, do not rewrite data from the point
table list screen or the servo amplifier's front panel. Otherwise, the set
values are made invalid.
The servo motor will not operate if the forced stop (EMG), forward
rotation stroke end (LSP) and reverse rotation stroke end (LSN) are off.
Make automatic ON setting to turn on these devices or make device
setting to assign them as external input signals and turn on across these
signals and SG. (Refer to Section 7.6.)
7 - 14