3. CC-Link COMMUNICATION FUNCTIONS

3.2.2 Wiring method

(1) Communication connector
The pin layout of the communication connector CN10 on the MR-J2S-T01 option unit is shown below.
(2) Connection example
The servo amplifier and PLC CC-Link master unit are wired as shown below. Refer to Section 15.2.1
(3) for the twisted pair cable used for connection.
(3) Example of connecting multiple servo units
As the remote I/O stations of CC-Link, servo amplifiers share the link system and can be
controlled/monitored using PLC user programs.
PLC CC-Link
Termination register
master unit
DA
DB
DG
SLD
FG
Note 1. Use the termination resistor supplied with the PLC. The resistance of the termination resistor depends on the cable used. For
details, refer to the open field network CC-Link catalog (L(NA)74108143).
2. Refer to this section (4).
PLC CC-Link
master unit
DA
DB
DG
SLD
MR-J2S-T01 option unit
CC-Link connector (CN10)
(Note 2) Shielded twisted cable (3-wire type)
Signal
Pin No.
name
1
DA
1
2
DB
2
3
DG
3
4
SLD
4
5
FG
5
MR-J2S-T01
CN10
DA
DB
DG
SLD
FG
(Note) Termination
register
1 DA
2 DB
3 DG
4 SLD
5 FG
3 - 3
MR-J2S-T01 option unit
CC-Link connector (CN10)
1 DA
2 DB
3 DG
4 SLD
5 FG
Max. number of axes: 42 stations
(When 1 station is occupied)