C) Motor Constant Parameters; Applied Motor - Mitsubishi Electric 800 Series Instruction Manual

600v class specification inverter
Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

5.13

(C) Motor constant parameters

Purpose
To select the motor to be used
To run by maximizing the
performance of the induction and
vector motors
To run by maximizing the
performance of the PM motor
To perform high accuracy operation
without being affected by
temperature and high-torque/ultra-
low speed
To use the motor with encoder
To detect signal loss of encoder
signals
5.13.1

Applied motor

By setting the applied motor type, the thermal characteristic appropriate for the motor can be selected.
When using a constant-torque or PM motor, the electronic thermal O/L relay is set according to the used motor.
Pr.
Name
71
Applied motor
C100
450
Second applied motor
C200
Parameter to set
Applicable motor
P.C100, P.C200
P.C000, P.C100 to
P.C105, P.C107,
P.C108, P.C110,
P.C120 to P.C126,
Offline auto tuning
P.C200 to P.C205,
P.C207, P.C208,
P.C210, P.C220 to
P.C226
P.C000, P.C100 to
P.C108, P.C110,
P.C120, P.C122,
P.C123, P.C126,
P.C130 to P.C133,
P.C135, P.C150,
PM motor offline
P.C182, P.C185,
auto tuning
P.C200 to P.C208,
P.C210, P.C220,
P.C222, P.C223,
P.C226,
P.C230 to P.C233,
P.C235, P.C282,
P.C285
Online auto tuning
P.C111, P.C211
Encoder
P.C140, P.C141,
specifications
P.C240, P.C241
Signal loss
P.C148, P.C248
detection
Initial value
Setting range
0 to 6, 13 to 16, 30, 33, 34,
0
8090, 8093, 8094, 9090,
9093, 9094
0, 1, 3 to 6, 13 to 16, 30,
33, 34, 8090, 8093, 8094,
9999
9090, 9093, 9094
9999
(C) Motor constant parameters
Pr.71, Pr.450
Pr.9, Pr.51, Pr.71,
Pr.80 to Pr.84,
Pr.90 to Pr.94, Pr.96,
Pr.453 to Pr.463,
Pr.684, Pr.707,
Pr.724, Pr.744,
Pr.745, Pr.859, Pr.860
Pr.9, Pr.51, Pr.71,
Pr.80, Pr.81, Pr.83,
Pr.84, Pr.90, Pr.92,
Pr.93, Pr.96, Pr.450,
Pr.453, Pr.454, Pr.456
to Pr.458, Pr.460,
Pr.461, Pr.463,
Pr.684, Pr.702,
Pr.706, Pr.707,
Pr.711, Pr.712,
Pr.717, Pr.721,
Pr.724, Pr.725, Pr.738
to Pr.747, Pr.788,
Pr.859, Pr.860,
Pr.1002, Pr.1412,
Pr.1413
Pr.95, Pr.574
Pr.359, Pr.369,
Pr.851, Pr.852
Pr.376, Pr.855
Description
By selecting a motor, the thermal
characteristic and motor constant of
each motor are set.
Set it when using the second motor.
(the same specifications as Pr.71)
The function is disabled.
PARAMETERS
Refer to
page
423
426
436
426
64
446
5
GROUP
C
423

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents