Selection of control source in Network operation mode (Pr.338, Pr.339)
• There are two control sources: the start command source, which controls the signals related to the inverter stand command
and function selection, and the speed command source, which controls signals related to frequency setting.
• The table below shows the commands from the external terminals and communication (RS-485 terminals or
communication option) in the Network operation mode.
Pr.338 Communication operation
Operation
command source
location
Pr.339 Communication speed
selection
command source
Frequency setting through
Fixed
communication
function
Terminal 2
(terminal-
equivalent
Terminal 4
function)
Terminal 1
Low-speed operation command/
0
RL
remote setting
Clear/Stop-on-contact selection 0
Middle-speed operation
1
RM
command/remote setting
deceleration
High-speed operation
2
RH
command/remote
setting acceleration
Second function selection/stop-
3
RT
on-contact selection 1
4
AU
Terminal 4 input selection
5
JOG
Jog operation selection
Selection of automatic restart
6
CS
after instantaneous power
failure, flying start
7
OH
External thermal relay input
8
REX
15-speed selection
9
X9
Third function selection
10
X10
Inverter run enable signal
FR-CC2 connection,
11
X11
instantaneous power failure
detection
12
X12
PU operation external interlock
External DC injection brake
13
X13
operation start
14
X14
PID control valid terminal
Brake opening completion
15
BRI
signal
PU/External operation
16
X16
switchover
Load pattern selection forward/
17
X17
reverse rotation boost
18
X18
V/F switchover
Load torque high-speed
19
X19
frequency
S-pattern acceleration/
20
X20
deceleration C switchover
22
X22
Orientation command
23
LX
Pre-excitation/servo ON
Output stop
24
MRS
PU operation interlock
STP
25
Start self-holding selection
(STOP)
26
MC
Control mode switchover
27
TL
Torque limit selection
(D) Operation command and frequency command
0: NET
0:
1:
2:
0:
NET
EXT
EXT
NET
NET
NET
NET
EXT
EXT
Compensation
NET
EXT
NET
NET
EXT
NET
NET
EXT
NET
NET
EXT
Combined
EXT
EXT/ NET
EXT
EXT
NET
EXT
NET
NET
EXT
EXT
EXT
EXT
NET
EXT
NET
EXT
NET
NET
EXT
EXT
NET
EXT
NET
EXT
NET
EXT
NET
EXT
NET
EXT
NET
EXT
Combined
EXT
EXT
-
EXT
NET
EXT
NET
EXT
1: EXT
REMARKS
1:
2:
EXT
EXT
NET
EXT
EXT
Pr.59 ="0" (multi-
speed)
Pr.59 "0" (remote)
EXT
Pr.270 ="1, 3, 11, or
13" (stop-on-contact)
EXT
Pr.270 ="1, 3, 11, or
13" (stop-on-contact)
Combined
EXT/ NET is selected
according to Pr.162
setting.

Pr.59 ="0" (multi-
EXT
speed)
EXT
Pr.79 ≠ "7"
Pr.79 = "7"
When X12 signal is
not assigned.