Mitsubishi Electric 800 Series Instruction Manual page 374

600v class specification inverter
Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

Setting
Signal
Positive
Negative
name
logic
logic
During position command
61
161
PBSY
operation
Home position return
63
163
ZP
completed
64
164
Y64
During retry
67
167
Y67
Power failure
24 V external power supply
68
168
EV
operation
70
170
SLEEP PID output interruption
Pulse train output of output
79
179
Y79
power
Position control preparation
84
184
RDY
ready
85
185
Y85
DC current feeding
Control circuit capacitor life
86
186
Y86
(for Pr.313 to Pr.322)
Main circuit capacitor life
87
187
Y87
(for Pr.313 to Pr.322)
Cooling fan life
88
188
Y88
(for Pr.313 to Pr.322)
Inrush current limit circuit life
89
189
Y89
(for Pr.313 to Pr.322)
90
190
Y90
Life alarm
Fault output 3 (power-OFF
91
191
Y91
signal)
Energy saving average
92
192
Y92
value updated timing
93
193
Y93
Current average monitor
94
194
ALM2
Fault output 2
95
195
Y95
Maintenance timer
96
196
REM
Remote output
97
197
ER
Alarm output 2
98
198
LF
Alarm
99
199
ALM
Fault
Function
Output during position command operation.
Output after home position return is completed.
Output during retry processing.
Output when the output is shut off due to power
failure or undervoltage, or the power failure time

deceleration-to-stop function is activated.
Output while operating with a 24 V power supply
input from an external source.
Output during PID output suspension function
operation.
Output in pulses every time the accumulated
output power of the inverter reaches the Pr.799
setting.
Output when the operation is set ready by servo
ON (LX ON)
Output when there is a power failure or

undervoltage for the AC current.
Output when the control circuit capacitor
approaches the end of its life.

Output when the main circuit capacitor
approaches the end of its life.

Output when the cooling fan approaches the end
of its life.

Output when the inrush current limit circuit
approaches the end of its life.

Output when any of the control circuit capacitor,
main circuit capacitor and inrush current limit
circuit or the cooling fan approaches the end of its
life.
Output when an error occurs due to an inverter
circuit fault or connection fault.
Switches between ON and OFF each time the
average power saving is updated when using the
power saving monitor.
This cannot be set in Pr.195 or Pr.196, Pr.320 to
Pr.322 (relay output terminal).
Outputs the average current and maintenance
timer value as a pulse.
This cannot be set in Pr.195 or Pr.196, Pr.320 to
Pr.322 (relay output terminal).
Output when the inverter's protective function is
activated to stop the output (at fault occurrence).
The signal output continues even during an
inverter reset, and the signal output stops after the
reset release.
Output when Pr.503 reaches the Pr.504 setting or
higher.
Output via terminals when certain parameters are
set.
When Pr.875 = "0" (initial value), output in the
same way as the ALM signal.
When Pr.875 = "1", if OHT/THM/PTC occurs, the
signal is output, and deceleration to a stop is
performed at the same time. When other
protective functions operate, output when output is
stopped.
Output when an alarm (fan fault or communication
error warning) occurs.
Output when the inverter's protective function is
activated to stop the output (at fault occurrence).
The signal output is stopped after a reset.
(M) Monitor display and monitor output signal
Operation

Refer
Related
to
parameter
page
207
Pr.65 to Pr.69
327
Pr.261 to Pr.266
526
54
Pr.127 to Pr.134,
488
Pr.575 to Pr.577
Pr.799
389
Pr.419,
225
Pr.428 to Pr.430
Pr.30
608
Pr.255 to Pr.259
262
378
Pr.52, Pr.54,
Pr.158,
365
Pr.891 to Pr.899
Pr.555 to Pr.557
267
378
Pr.503, Pr.504
266
Pr.495 to Pr.497
385
Pr.875
323
324,
Pr.121, Pr.244
546
378
373
PARAMETERS