(F) Setting of acceleration/deceleration time and acceleration/deceleration pattern
• When the remotely-set frequency
is cleared by turning ON the RL
(clear) signal after turning OFF
(ON) both the RH and RM
signals, the inverter operates at
the frequency in the remotely-set
frequency cleared state if power
is reapplied before one minute
has elapsed since turning OFF
(ON) both the RH and RM
signals.
CAUTION
 When using the remote setting function, set the maximum frequency again according to the
machine.
Parameters referred to
???????
Pr.1 Maximum frequency, Pr.18 High speed maximum frequency
Pr.7 Acceleration time, Pr.8 Deceleration time, Pr.44 Second acceleration/deceleration time, Pr.45 Second deceleration time
Pr.28 Multi-speed input compensation selection
Pr.178 to Pr.182 (Input terminal function selection)
282
PARAMETERS
Remotely-set frequency stored last time
Acceleration (RH)
Deceleration (RM) OFF
Clear (RL)
Forward rotation
(STF)
Power supply
page 329
page 314
page 415
Within 1 minute
Remotely-set frequency stored last time
ON
ON
ON
ON
Time
ON
ON
page 269