Pr.
Pr.
group
Regeneration avoidance operation
882
G120
selection
Regeneration avoidance operation
883
G121
level
Regeneration avoidance at
884
G122
deceleration detection sensitivity
Regeneration avoidance
885
G123
compensation frequency limit value
Regeneration avoidance voltage
886
G124
gain
888
E420
Free parameter 1
889
E421
Free parameter 2
Cumulative power monitor digit
891
M023
shifted times
892
M200
Load factor
Energy saving monitor reference
893
M201
(motor capacity)
Control selection during
894
M202
commercial power-supply
operation
895
M203
Power saving rate reference value
896
M204
Power unit cost
897
M205
Power saving monitor average time
Power saving cumulative monitor
898
M206
clear
Operation time rate (estimated
899
M207
value)
900
M310
FM terminal calibration
901
M320
AM terminal calibration
Terminal 2 frequency setting bias
902
T200
frequency
902
T201
Terminal 2 frequency setting bias
903
Terminal 2 frequency setting gain
T202
(125)
frequency
903
T203
Terminal 2 frequency setting gain
Terminal 4 frequency setting bias
904
T400
frequency
904
T401
Terminal 4 frequency setting bias
905
Terminal 4 frequency setting gain
T402
(126)
frequency
905
T403
Terminal 4 frequency setting gain
917
T100
Terminal 1 bias frequency (speed)
917
T101
Terminal 1 bias (speed)
918
T102
Terminal 1 gain frequency (speed)
918
T103
Terminal 1 gain (speed)
Name
Setting range
0 to 2
300 to 1200 V
0 to 5
0 to 590 Hz, 9999
0 to 200%
0 to 9999
0 to 9999
0 to 4, 9999
30 to 150%
0.1 to 55 kW
0 to 3600 kW
0 to 3
0, 1, 9999
0 to 500, 9999
0 to 1000 h, 9999
0, 1, 10, 9999
0 to 100%, 9999
-
-
0 to 590 Hz
0 to 300%
0 to 590 Hz
0 to 300%
0 to 590 Hz
0 to 300%
0 to 590 Hz
0 to 300%
0 to 590 Hz
0 to 300%
0 to 590 Hz
0 to 300%
Parameter list (by parameter number)
Minimum
setting
Initial value
increments
1
0
0.1V
940 V DC
1
0
0.01 Hz
6 Hz
0.1%
100%
1
9999
1
9999
1
9999
0.1%
100%
0.01 kW


Rated inverter
capacity
0.1 kW


1
0
1
9999
0.01
9999
1 h
9999
1
9999
0.1%
9999
-
-
-
-
0.01 Hz
0 Hz
0.1%
0%
0.01 Hz
60 Hz
0.1%
100%
0.01 Hz
0 Hz
0.1%
20%
0.01 Hz
60 Hz
0.1%
100%
0.01 Hz
0 Hz
0.1%
0%
0.01 Hz
60 Hz
0.1%
100%
PARAMETERS
Parameter List
Refer
to
page
Pr.
614
List
614
614
614
614
255
255
347,
365
365
365
365
365
365
365
365
365
362
362
402
402
402
402
402
402
402
402
402
402
402
5
402
115