(M) Monitor display and monitor output signal
NOTE
• When indication with negative numbers is enabled for the output via terminal AM (analog voltage output), the output is within
the range of -10 to +10 VDC. Connect a meter suitable for the output.
• Parameter unit displays only unsigned numbers.
Monitor filter (Pr.1106 to Pr.1108)
• The response level (filter time constant) of the following monitor indicators can be adjusted.
Pr.
Monitor number
7
17
1106
32
33
1107
6
1108
18
Parameters referred to
???????
Pr.30 Regenerative function selection, Pr.70 special regenerative brake duty
Pr.37 motor speed display, Pr.144 Speed setting switchover
Pr.55 Frequency monitoring reference, Pr.56 Current monitoring reference, Pr.866 Torque monitoring reference
356
PARAMETERS
Monitor indicator name
Motor torque
Load meter
Torque command
Torque current command
Running speed
Motor excitation current
page 345
page 608
page 357