(E) Environment setting parameters
GOT initial setting (RS-485 terminals) (Pr.999 = "11, 13")
Pr.
79
Operation mode selection
332
RS-485 communication speed
333
RS-485 communication stop bit length
334
RS-485 communication parity check selection
335
RS-485 communication retry count
336
RS-485 communication check time interval
337
RS-485 communication waiting time setting
340
Communication startup mode selection
341
RS-485 communication CR/LF selection
414
PLC function operation selection
549
Protocol selection

When Pr.414="1", the setting value is not changed.
• Initial setting with the GOT2000 series
- When "FREQROL 500/700/800, SENSORLESS SERVO" is selected for "Controller Type" in the GOT setting, set
Pr.999="11" to configure the GOT initial setting.
- When "FREQROL 800(Automatic Negotiation)" is selected for "Controller Type" in the GOT setting, the GOT automatic
connection can be used. When "FREQROL 800 (Automatic Negotiation)" is selected for "Controller Type" in the GOT setting
and the GOT automatic connection is not used, set Pr.999="13" to configure the GOT initial setting. (Refer to
• Initial setting with the GOT1000 series
- Set Pr.999="11" to configure the GOT initial setting.
NOTE
• Always perform an inverter reset after the initial setting.
• For the details of connection with GOT, refer to the Instruction Manual of GOT.
Rated frequency (Pr.999 = "20 (50 Hz), 21 (60 Hz)")
Pr.
3
Base frequency
4
Multi-speed setting (high speed)
20
Acceleration/deceleration reference frequency
37
Speed display
55
Frequency monitoring reference
Stall prevention operation reduction starting
66
frequency
116
Third output frequency detection
125 (903)
Terminal 2 frequency setting gain frequency
126 (905)
Terminal 4 frequency setting gain frequency
263
Subtraction starting frequency
Power failure deceleration time switchover
266
frequency
386
Frequency for maximum input pulse
505
Speed setting reference
808
Forward rotation speed limit/speed limit
918
Terminal 1 gain frequency (speed)
258
PARAMETERS
Name
Name
Initial
Pr.999="11"
value
0
0
96
192
1
10
2
1
1
9999
0 s
9999
9999
0 ms
0
1
1
1
0
0
0
Initial
Pr.999 = "21" Pr.999 = "20"
value
60 Hz
60 Hz
60 Hz
60 Hz
60 Hz
60 Hz
0
0
60 Hz
60 Hz
60 Hz
60 Hz
60 Hz
60 Hz
60 Hz
60 Hz
60 Hz
60 Hz
60 Hz
60 Hz
60 Hz
60 Hz
60 Hz
60 Hz
60 Hz
60 Hz
60 Hz
60 Hz
60 Hz
60 Hz
Refer to
Pr.999="13"
page
0
291
1152
0
1
553
9999
9999
0 ms
1
300
1
553
2
531

0
569
page
585)
Refer to
page
50 Hz
591
50 Hz
314
50 Hz
269
345
50 Hz
357
50 Hz
332
50 Hz
332
50 Hz
402
50 Hz
50 Hz
526
50 Hz
50 Hz
308
50 Hz
345
50 Hz
195
50 Hz
402