Mitsubishi Electric 800 Series Instruction Manual page 141

600v class specification inverter
Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

Control method
2) Output terminal function selection (Pr.190 to Pr.196)
• Electronic thermal O/L relay pre-alarm (THP)
• Brake opening request (BOF)
• Second brake opening request (BOF2)
• Orientation complete (ORA)
• Orientation fault (ORM)
• Regenerative status output (Y32)
• In-position (Y36)
• Travel completed (MEND)
• Start time tuning completion (Y39)
• Home position return failure (ZA)
• Position detection level (FP)
• During position command operation (PBSY)
• Home position return completed (ZP)
Parameters referred to
???????
Pr.178 to Pr.189 (Input terminal function selection)
Pr.190 to Pr.196 (Output terminal function selection)
Valid/invalid status of monitor outputs during the test run
 : Valid
 : Invalid (always displays 0)
∆ : Displays accumulated value before the test
― : Not monitored
Types of monitor
Output frequency
Fault display
Frequency setting value
Running speed
Converter output voltage
Electric thermal relay load factor
Output current peak value
Converter output voltage peak
value
Load meter
Cumulative energization time
Reference voltage output
Actual operation time
Cumulative power
Trace status
Station number
(RS-485 terminals)
Station number (PU connector)
Station number (CC-Link)
Energy saving effect
Cumulative energy saving
PID set point
PID measured value
PID deviation
Input terminal status
Output terminal status
Option input terminal status
Parameters referred to
???????
Pr.52 Operation panel main monitor selection
Pr.158 AM terminal function selection
140
PARAMETERS
page 415
page 370
DU/PU
FM/AM
Monitor
Output
display





page 347
page 357
Types of monitor
Option output terminal status
Motor thermal load factor
Inverter thermal load factor
PTC thermistor value
PID measured value 2
Remote output 1
Remote output 2
Remote output 3
Remote output 4
PID manipulated amount
Second PID set point
Second PID measured value
Second PID deviation
Second PID measured value 2
Second PID manipulated amount 
Dancer main speed setting

Different output interface (operation panel, parameter
unit, terminal FM or terminal AM) can output different
monitored items. For details, refer to

When the operation is switched to the test run, "0" is
displayed. When PM sensorless vector control is selected
again after a test run, the output current peak value and
the electronic thermal relay load factor from the last
operation are displayed.

The monitored status can be output via the terminal AM
only.

When the operation is switched to the test run,
accumulated thermal value is reduced by considering the
output current is "0".
DU/PU
FM/AM
Monitor
Output
display







page
357.