Output signal list
• The functions of the output terminals can be set.
• Refer to the following table and set each parameter. (0 to 99: Positive logic, 100 to 199, 300 to 399: Negative logic)
Setting
Signal
Positive
Negative
name
logic
logic
0
100
RUN
Inverter running
1
101
SU
Up to frequency
Instantaneous power failure/
2
102
IPF
undervoltage
3
103
OL
Overload warning
4
104
FU
Output frequency detection
Second output frequency
5
105
FU2
detection
Third output frequency
6
106
FU3
detection
Regenerative brake pre-
7
107
RBP
alarm
Electronic thermal O/L relay
8
108
THP
pre-alarm
10
110
PU
PU operation mode
11
111
RY
Inverter operation ready
12
112
Y12
Output current detection
13
113
Y13
Zero current detection
14
114
FDN
PID lower limit
15
115
FUP
PID upper limit
PID forward/reverse rotation
16
116
RL
output
17
MC1
Electronic bypass MC1
18
MC2
Electronic bypass MC2
19
MC3
Electronic bypass MC3
20
120
BOF
Brake opening request
Second brake opening
22
122
BOF2
request
25
125
FAN
Fan fault output
Heat sink overheat pre-
26
126
FIN
alarm
Orientation complete
27
127
ORA
(for vector control
compatible option)
Orientation fault
28
128
ORM
(for vector control
compatible option)
Function
Output during operation when the inverter output
frequency reaches Pr.13 Starting frequency or
higher.
Output when the output frequency reaches the set

frequency.
Output when an instantaneous power failure or
undervoltage protection operation occurs.

Output during operation of the stall prevention
function.
Output when the output frequency reaches the
frequency set in Pr.42 (Pr.43 during reverse
rotation) or higher.
Output when the output frequency reaches the
frequency set in Pr.50 or higher.
Output when the output frequency reaches the
frequency set in Pr.116 or higher.
Output when 85% of the regenerative brake duty
set in Pr.70 is reached.

Output when the cumulative electronic thermal O/
L relay value reaches 85% of the trip level.
(Electronic thermal O/L relay protection (E.THT/
E.THM) is activated when the value reaches
100%.)
Output when PU operation mode is selected.
Output when the reset process is completed after
powering ON the inverter (when starting is
possible by switching the start signal ON or during
operation).
Output when the output current is higher than the
Pr.150 setting for the time set in Pr.151 or longer.
Output when the output current is lower than the
Pr.152 setting for the time set in Pr.153 or longer.
Output when the value is lower than the lower limit
of PID control.
Output when the value is higher than the upper
limit of PID control.
Output during forward rotation under PID control.
Used when using the electronic bypass function.
Output to open the brake when the brake
sequence function is selected.
Output to open the brake when the second brake
sequence function is selected (RT signal ON).
Output when a fan fault occurs.
Output when the heat sink temperature reaches
about 85% of the heat sink overheat protection
operation temperature.

When orientation is enabled.

(M) Monitor display and monitor output signal
Operation
Refer
Related
to
parameter
page
375
Pr.41
379
Pr.57
515
Pr.22, Pr.23, Pr.66,
Pr.148, Pr.149,
332
Pr.154
Pr.42, Pr.43
379
Pr.50
379
Pr.116
379
Pr.70
608
Pr.9
317
Pr.79
291
375
Pr.150, Pr.151
382
Pr.152, Pr.153
382
Pr.127 to Pr.134,
488
Pr.575 to Pr.577
Pr.135 to Pr.139,
448
Pr.159
Pr.278 to Pr.285,
Pr.292
457
Pr.641 to Pr.649,
Pr.292
Pr.244
324
638
Pr.350 to Pr.366,
Pr.369, Pr.393,
473
Pr.396 to Pr.399
371
PARAMETERS
5
GROUP
M