Mitsubishi Electric 800 Series Instruction Manual page 699

600v class specification inverter
Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

Pr.
Name
859
Torque current/Rated PM motor current
Second motor torque current/Rated PM
860
motor current
Encoder option selection
862
Control terminal option-Encoder pulse
863
division ratio
864
Torque detection
865
Low speed detection
866
Torque monitoring reference
867
AM output filter
868
Terminal 1 function assignment
870
Speed detection hysteresis
872
Input phase loss protection selection
873
Speed limit
874
OLT level setting
875
Fault definition
876
Thermal protector input
Speed feed forward control/model adaptive
877
speed control selection
878
Speed feed forward filter
879
Speed feed forward torque limit
880
Load inertia ratio
881
Speed feed forward gain
Regeneration avoidance operation
882
selection
883
Regeneration avoidance operation level
Regeneration avoidance at deceleration
884
detection sensitivity
Regeneration avoidance compensation
885
frequency limit value
886
Regeneration avoidance voltage gain
888
Free parameter 1
889
Free parameter 2
Cumulative power monitor digit shifted
891
times
892
Load factor
Energy saving monitor reference (motor
893
capacity)
Control selection during commercial power-
894
supply operation
895
Power saving rate reference value
896
Power unit cost
897
Power saving monitor average time
898
Power saving cumulative monitor clear
899
Operation time rate (estimated value)
900
FM terminal calibration
901
AM terminal calibration
902
Terminal 2 frequency setting bias frequency 5E DE 1
902
Terminal 2 frequency setting bias
903
Terminal 2 frequency setting gain frequency 5F DF 1
(125)
903
Terminal 2 frequency setting gain
904
Terminal 4 frequency setting bias frequency 60 E0 1
904
Terminal 4 frequency setting bias
905
Terminal 4 frequency setting gain frequency 61 E1 1
(126)
905
Terminal 4 frequency setting gain
917
Terminal 1 bias frequency (speed)
698
APPENDIX
Instruction
code

3B BB 8
3C BC 8
3E BE 8
3F BF 8
40 C0 8
41 C1 8
42 C2 8
43 C3 8
44 C4 8
46 C6 8
48 C8 8
49 C9 8
()
4A CA 8
4B CB 8
4C CC 8
4D CD 8
4E CE 8
4F CF 8
50 D0 8
51 D1 8
52 D2 8
53 D3 8
54 D4 8
55 D5 8
56 D6 8
58 D8 8
59 D9 8
5B DB 8
5C DC 8
5D DD 8
5E DE 8
5F DF 8
60 E0 8
61 E1 8
62 E2 8
63 E3 8
5C DC 1
5D DD 1
5E DE 1
5F DF 1
60 E0 1
61 E1 1
11 91 9
Control method

Vector
Vector
Vector
Sensorless
Sensorless
Sensorless

Parameter
PM
PM
PM