Mitsubishi Electric 800 Series Instruction Manual page 307

600v class specification inverter
Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

(D) Operation command and frequency command
Pr.338 Communication operation
Operation
command source
location
Pr.339 Communication speed
selection
command source
Start-time tuning start external
28
X28
input
32
X32
External fault input
37
X37
Traverse function selection
42
X42
Torque bias selection 1
43
X43
Torque bias selection 2
44
X44
P/PI control switchover
Second brake sequence open
45
BRI2
completion
46
TRG
Trace trigger input
47
TRC
Trace sampling start/end
48
X48
Power failure stop external
50
SQ
Sequence start
51
X51
Fault clear
52
X52
Cumulative pulse monitor clear
Cumulative pulse monitor clear
53
X53
(control terminal option)
57
JOGF
JOG forward rotation command —
58
JOGR
JOG reverse rotation command —
59
CLRN
NET position pulse clear
60
STF
Forward rotation command
61
STR
Reverse rotation command
62
RES
Inverter reset
PID forward/reverse action
64
X64
switchover
65
X65
PU/NET operation switchover
External/NET operation
66
X66
switchover
67
X67
Command source switchover
68
NP
Simple position pulse train sign
Simple position droop pulse clear
69
CLR
DC feeding operation
70
X70
permission
71
X71
DC feeding cancel
72
X72
PID P control switchover
Second PID P control
73
X73
switchover
Magnetic flux decay output
74
X74
shutoff signal
76
X76
Proximity dog
77
X77
Pre-charge end command
Second pre-charge end
78
X78
command
Second PID forward/reverse
79
X79
action switchover
Second PID control valid
80
X80
terminal
SSCNET III communication
85
X85
disabled
87
X87
Sudden stop
88
LSP
Upper stroke limit
89
LSN
Lower stroke limit
92
X92
Emergency stop
93
X93
Torque limit selection
Control signal input for main
94
X94
circuit power supply MC
95
X95
Converter unit fault input
Converter unit fault (E.OHT,
96
X96
E.CPU) input

When Pr.77 = "2", Pr.162 setting can be changed during operation. The new setting is applied after stop. Until the inverter has stopped, the
previous setting of the interface for the operation command and the speed command in the Network operation mode is valid.
306
PARAMETERS
0: NET
0:
1:
2:
NET
EXT
EXT
NET
EXT
EXT
NET
EXT
NET
EXT
NET
EXT
NET
EXT
NET
EXT
Combined
EXT
Combined
EXT
EXT
EXT, NET
EXT
Combined
EXT
NET
EXT
NET
EXT
EXT
EXT
NET
NET
EXT
NET
EXT
EXT
NET
EXT
NET
EXT
EXT
EXT
EXT
EXT
NET
EXT
NET
EXT
NET
EXT
NET
NET
EXT
NET
NET
EXT
EXT
NET
EXT
NET
NET
EXT
NET
NET
EXT
NET
NET
EXT
NET
EXT
Combined
EXT
EXT
EXT
EXT
NET
EXT
EXT
EXT
EXT
1: EXT
0:
1:
2:
NET
EXT
EXT
Pr.414="1": Valid
when there is external
or network input
Pr.414="2": External
EXT
EXT
EXT
EXT
EXT
EXT
EXT
REMARKS