Mitsubishi Electric 800 Series Instruction Manual page 125

600v class specification inverter
Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

Parameter List
Parameter list (by function group)
Pr.
Pr.
group
Third stall prevention operation
H603
115
frequency
Stall prevention operation level
H610
23
compensation factor at double speed
Stall prevention operation reduction
H611
66
starting frequency
H620
148
Stall prevention level at 0 V input
H621
149
Stall prevention level at 10 V input
Voltage reduction selection during stall
H631
154
prevention operation
H700
810
Torque limit input method selection
H701
812
Torque limit level (regeneration)
H702
813
Torque limit level (3rd quadrant)
H703
814
Torque limit level (4th quadrant)
H704
801
Output limit level
H710
815
Torque limit level 2
H720
816
Torque limit level during acceleration
H721
817
Torque limit level during deceleration
H730
874
OLT level setting
H800
374
Overspeed detection level
H881
690
Deceleration check time
 M: Monitor display and monitor output signal
Parameters regarding the inverter's operating status. These
parameters are used to set the monitors and output signals.
Pr.
Pr.
group
M000
37
Speed display
M001
505
Speed setting reference
M002
144
Speed setting switchover
M020
170
Watt-hour meter clear
M021
563
Energization time carrying-over times
M022
268
Monitor decimal digits selection
Cumulative power monitor digit
M023
891
shifted times
M030
171
Operation hour meter clear
M031
564
Operating time carrying-over times
M040
55
Frequency monitoring reference
M041
56
Current monitoring reference
M042
866
Torque monitoring reference
M043
241
Analog input display unit switchover
M044
290
Monitor negative output selection
M045
1018
Monitor with sign selection
M050
1106
Torque monitor filter
M051
1107
Running speed monitor filter
M052
1108
Excitation current monitor filter
Control circuit temperature signal
M060
663
output level
Operation panel main monitor
M100
52
selection
M101
774
Operation panel monitor selection 1
M102
775
Operation panel monitor selection 2
M103
776
Operation panel monitor selection 3
M104
992
Parameter for manufacturer setting. Do not set.
M200
892
Load factor
Energy saving monitor reference
M201
893
(motor capacity)
Control selection during commercial
M202
894
power-supply operation
M203
895
Power saving rate reference value
M204
896
Power unit cost
M205
897
Power saving monitor average time
Power saving cumulative monitor
M206
898
clear
124
PARAMETERS
Refer
Name
to page
332
332
332
332
332
332
154
154
154
154
154,
190
154
154
154
154
343
180
Refer
Name
to page
345
345
345
347
347
347
347,
365
347
347
357
357
357
402
347,
357
347
347
347
347
390
347
347
347
347
365
365
365
365
365
365
365
Pr.
Pr.
group
M207
899
Operation time rate (estimated value)
M300
54
FM terminal function selection
M301
158
AM terminal function selection
M310
900
FM terminal calibration
M320
901
AM terminal calibration
M321
867
AM output filter
M400
190
RUN terminal function selection
M401
191
SU terminal function selection
M402
192
IPF terminal function selection
M403
193
OL terminal function selection
M404
194
FU terminal function selection
M405
195
ABC1 terminal function selection
M406
196
ABC2 terminal function selection
M410
313

DO0 output selection
M411
314

DO1 output selection
M412
315

DO2 output selection
M413
316

DO3 output selection
M414
317

DO4 output selection
M415
318

DO5 output selection
M416
319

DO6 output selection
M420
320

RA1 output selection
M421
321

RA2 output selection
M422
322

RA3 output selection
M430
157
OL signal output timer
M431
289
Inverter output terminal filter
Output current detection signal
M433
166
retention time
M440
870
Speed detection hysteresis
M441
41
Up-to-frequency sensitivity
M442
42
Output frequency detection
Output frequency detection for
M443
43
reverse rotation
M444
50
Second output frequency detection
M445
116
Third output frequency detection
M446
865
Low speed detection
M460
150
Output current detection level
Output current detection signal delay
M461
151
time
M462
152
Zero current detection level
M463
153
Zero current detection time
Output current detection operation
M464
167
selection
M470
864
Torque detection
M500
495
Remote output selection
M501
496
Remote output data 1
M502
497
Remote output data 2
M510
76
Fault code output selection
Pulse increment setting for output
M520
799
power
M530
655
Analog remote output selection
M531
656
Analog remote output 1
M532
657
Analog remote output 2
M533
658
Analog remote output 3
M534
659
Analog remote output 4
Control terminal option-Encoder pulse
M600
863

division ratio
M601
413

Encoder pulse division ratio
Cumulative pulse clear signal
M610
635

selection
Cumulative pulse division scaling
M611
636

factor
Control terminal option-Cumulative
M612
637

pulse division scaling factor
M613
638

Cumulative pulse storage
Refer
Name
to page
365
357
357
362
362
362
370
370
370
370
370
370
370
370
370
370
370
370
370
370
370
370
370
154,
332
370
382
379
379
379
379
379
379
379
382
382
382
382
382
384
385
385
385
388
389
386
386
386
386
386
391
391
227
227
227
227