Clearing condition
Servo-OFF (LX-OFF)
×
(output shutoff)
Clear signal input
○
Home position return
×
completed
When position control is
switched to other control
○
mode
Clear signal input
(When position control is
×
switched to other control
mode)
: Cleared,
: Not cleared
○
×
The droop pulses are not cleared.
The CLR/CLRN signal is input when a value other than "1" is set in Pr.419, and the signal is input through terminal CR of the FR-A8AL when
Pr.419 = "1".
Pulses are cleared when a clear signal is input. (The home position information is not retained.)
Pulses are cleared only when the home position return is completed. Once the pulses are cleared, they are not cleared even if the LX signal is
turned ON.
The data is cleared when absolute position control is disabled.
The home position return is not available.
The following shows the example of the clearing the value of the current position 2 monitor under the control mode other than the position
control mode.
MC
ON
STF
Monitoring of
current position 2
0
Position
control
Not cleared to 0 at
the control switchover
Pulse monitoring on the operation panel
• The position command, current position and the status of droop pulses can be displayed on the operation panel.
• If displayed data has signs, minus signs appear for both upper and lower digits.
• If -99999999 or 99999999 is exceeded on the pulse monitor, the monitor value is reset to 0.
Display data
Lower monitor
-10000
Upper monitor
Lower monitor
-100
Upper monitor
NOTE
• The pulse count starts at servo on.
0
10
100
110
×
×
×
○
○
○
×
○
○
○
○
○
×
×
×
OFF
ON
ON
Monitor value
updated
Other than position
Position
control (speed)
control
Not cleared to 0 at
the control switchover
Monitor display without signs
Position control under vector control
Current position 2
Pr.419 setting
1, 2
1110
200
×
×
×
○
×
○
—
○
×
○
○
×
×
×
○
STF
ON
CLR
OFF
Monitoring of
current position 2
0
Other than position control (speed)
Monitor display with signs
210
300
310
1310
×
×
×
×
○
○
○
×
×
○
○
○
×
×
×
×
○
○
○
○
OFF
ON
Cleared to 0
by turning ON
of the CLR signal
PARAMETERS
5
229