Mitsubishi Electric 800 Series Instruction Manual page 490

600v class specification inverter
Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

Pr.
Name
609
PID set point/deviation
A624
input selection
610
PID measured value
A625
input selection
1015
Integral stop selection
A607
at limited frequency
753
Second PID action
A650
selection
Second PID control
754
automatic switchover
A652
frequency
755
Second PID action set
A651
point
756
Second PID
A653
proportional band
757
Second PID integral
A654
time
758
Second PID differential
A655
time
Second PID set point/
1140
deviation input
A664
selection
1141
Second PID measured
A665
value input selection
1143
Second PID upper limit
A641
1144
Second PID lower limit
A642
1145
Second PID deviation
A643
limit
1146
Second PID signal
A644
operation selection
Second output
1147
interruption detection
A661
time
Second output
1148
interruption detection
A662
level
1149
Second output
A663
interruption cancel level
Initial
Setting range
value
1
2
2
3
4
5
1
2
3
3
4
5
0
1
2
0
10
11
12
0, 10, 11, 20, 21,
50, 51, 60, 61, 70,
71, 80, 81, 90, 91,
0
100, 101, 1000,
1001, 1010, 1011,
2000, 2001, 2010,
2011
9999
0 to 600 Hz, 9999
9999
0 to 100%, 9999
0.1 to 1000%,
100
9999
0.1 to 3600 s,
1 s
9999
9999
0.01 to 10 s, 9999 Refer to Pr.134.
2
1 to 5
3
1 to 5
9999
0 to 100%, 9999
9999
0 to 100%, 9999
9999
0 to 100%, 9999
0
0 to 3, 10 to 13
1 s
0 to 3600 s, 9999
0 Hz
0 to 600 Hz
1000%
900 to 1100%
(A) Application parameters
Description
Input of set point, deviation value from terminal 1
Input of set point, deviation value from terminal 2
Input of set point, deviation value from terminal 4
Input of set point, deviation value via communication
Input of set point, deviation value by PLC function
Input of measured value from terminal 1
Input of measured value from terminal 2
Input of measured value from terminal 4
Input of measured value via communication
Input of measured value by sequence function
Integral stopped at the limit, manipulation range of ±100%,
integral cleared during output interruption
Integral continued at the limit, manipulation range of ±100%,
integral cleared during output interruption
Integral stopped at the limit, manipulation range of 0 to
100%, integral cleared during output interruption
Integral stopped at the limit, manipulation range of ±100%,
integral stopped during output interruption
Integral continued at the limit, manipulation range of ±100%,
integral stopped during output interruption
Integral stopped at the limit, manipulation range of 0 to
100%, integral stopped during output interruption
Refer to Pr.128.
Refer to Pr.127.
Refer to Pr.133.
Refer to Pr.129.
Refer to Pr.130.
Set the second PID control.
Refer to Pr.609.
For how to enable the second PID
control, refer to
Refer to Pr.610.
Refer to Pr.131.
Refer to Pr.132.
Refer to Pr.553.
(Y205 signal is
output.)
Refer to Pr.554.
Refer to Pr.575.
Refer to Pr.576.
Refer to Pr.577.
PARAMETERS
page
499.
5
GROUP
A
489

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents