Mitsubishi Electric 800 Series Instruction Manual page 159

600v class specification inverter
Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

Speed control under Real sensorless vector control, vector control, PM sensorless vector
control
• Functions of terminals 1 and 4 by control (―
Pr.858 setting
value

0
Speed command (AU signal-ON)
(Initial value)
Magnetic flux command

1

Magnetic flux command
Torque limit (Pr.810 = 1)
Power driving torque limit (Pr.810 = 1)
Torque limit (Pr.810 = 1)
4


Torque limit (Pr.810 = 1)
9999

When Pr.868 ≠ "0", the other functions of terminal 1 (auxiliary input, override function, PID control) do not operate.

When Pr.858 ≠ "0", PID control and speed commands using terminal 4 do not operate even when the AU signal is ON.

When both Pr.858 and Pr.868 are "1" (magnetic flux command) or "4" (torque limit), the function of terminal 1 has higher priority, and terminal 4
does not function.

Valid when vector control compatible options are installed and vector control is selected.
158
PARAMETERS
: no function)
Terminal 4 function


Pr.868 setting

0
Speed setting auxiliary
(Initial value)
1
Magnetic flux command

2
3
4
Torque limit (Pr.810 = 1)
5
6
Torque bias (Pr.840=1 to 3)
9999
0
Speed setting auxiliary
(Initial value)
1
Magnetic flux command

2
3
4
Torque limit (Pr.810 = 1)
5
6
Torque bias (Pr.840=1 to 3)
9999
0
Speed setting auxiliary
(Initial value)
1
Magnetic flux command

2
Regenerative driving torque limit (Pr.810 = 1)
3
4
Torque limit (Pr.810 = 1)
5
6
Torque bias (Pr.840 = 1 to 3)
9999
Terminal 1 function


