Mitsubishi Electric 800 Series Instruction Manual page 305

600v class specification inverter
Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

(D) Operation command and frequency command
Condition
Command
(Pr.551
source
setting)
External
terminal at the
control circuit

Follows the Pr.338 Communication operation command source and Pr.339 Communication speed command source settings. (Refer to
page
301.)

At occurrence of RS-485 communication error, the inverter cannot be reset from the computer.

PU stop is only enabled. PS is displayed on the operation panel during PU stop. Follows the Pr.75 Reset selection/disconnected PU
detection/PU stop selection setting. (Refer to

Writing of some parameters may be disabled by the Pr.77 Parameter write selection setting and the operating condition. (Refer to

Some parameters are write-enabled independently of the operation mode and command source presence/absence. Writing is also enabled
when Pr.77="2". (Refer to

When Pr.550 NET mode operation command source selection="1" (RS-485 terminals enabled), or Pr.550 NET mode operation command
source selection="9999" with no communication option connected.

When Pr.550 NET mode operation command source selection="0" (communication option enabled), or Pr.550 NET mode operation
command source selection="9999" with communication option connected.
Operation at fault
Conditions
Fault record
(Pr.551 setting)
Inverter fault
2 (PU connector)
9999 (automatic
PU connector
recognition)
disconnection
Other than 2
Communication
2 (PU connector)
error at PU
connector
Other than 2
1 (RS-485
Communication
terminals)
error at RS-485
terminals
Other than 1
3 (USB
connector)
Communication
9999 (automatic
error at USB
recognition)
connector
Other than 3
Communication
error at
communication
option

Selectable with Pr.75 Reset selection/disconnected PU detection/PU stop selection

Selectable with Pr.122 PU communication check time interval, Pr.336 RS-485 communication check time interval, and Pr.548 USB
communication check time interval

Follows the communication option

In the PU JOG operation mode, operation always stops when the PU is disconnected. The operation of PU disconnection (E.PUE) follows the
Pr.75 Reset selection/disconnected PU detection/PU stop selection setting.

When Pr.550 NET mode operation command source selection= "1" (RS-485 terminals enabled), or Pr.550 NET mode operation command
source selection="9999" with no communication option connected.

When Pr.550 NET mode operation command source selection="0" (communication option enabled), or Pr.550 NET mode operation
command source selection="9999" with communication option connected.
304
PARAMETERS
Item
PU
operation
Inverter reset
Operation command
(start, stop)
Frequency setting
page
244.)
page
251.) Parameter clear is disabled.
Operation in each operation mode at error occurrences
PU
External
operation
operation
Stop
Stop/continued

Stop/continued

Stop/continued
Continued

Continued
Stop/continued
Continued

Continued
Stop/continued
Continued

Continued
Continued
Controllability in each operation mode
External/PU
External/PU
combined
combined
External
operation
operation
operation
mode 1
mode 2
(Pr.79 =3)
(Pr.79 =4)
External/PU
External/PU
combined
combined
operation
operation
mode 1
mode 2
(Pr.79 =3)
(Pr.79 =4)
Stop/
continued
Stop/
continued
NET operation
NET operation
(when
(when RS-485
communication
terminals are
option is used)
used)



: Valid
: Invalid
: Partially valid
NET
NET operation
operation
(when
(when RS-485
communication
terminals are
option is
used)
used)

Continued

Continued

Stop/continued
Continued

Stop/continued


page
251.)
