(E) Environment setting parameters
5.7.1

Real time clock function

The time can be set. The time can only be updated while the inverter power is ON.
The real time clock function is enabled using an optional LCD operation panel (FR-LU08).
Pr.
Name
1006
Clock (year)
E030
1007
Clock (month, day)
E031
1008
Clock (hour, minute)
E032
Simple clock function
• When the year, month, day, time and minute are set in the parameters, the inverter counts the date and time. The date and
time can be checked by reading the parameters.
NOTE
• The clock's count-up data is saved in the inverter's EEPROM every 10 minutes.
• Because the date and time are cleared after turning OFF the control circuit power supply, the clock function must be reset
after turning ON the power supply. Use a separate power supply, such as an external 24 V power supply, for the control circuit
of the simple clock function, and supply power continuously to this control circuit.
• In the initial setting, inverter reset is performed if supplying power to the main circuit is started when power is supplied only to
the control circuit. Then, the clock information stored in EEPROM is restored. Reset at the start of supplying power to the
main circuit can be disabled by setting Pr.30 Regenerative function selection. (Refer to
• The set clock is also used for functions such as the fault history.
242
PARAMETERS
Initial
Setting range
value
2000
2000 to 2099
101 to 131, 201 to 228,
(229), 301 to 331,
401 to 430, 501 to 531,
101
601 to 630, 701 to 731,
(January 1)
801 to 831, 901 to 930,
1001 to 1031, 1101 to 1130,
1201 to 1231
0 to 59, 100 to 159,
200 to 259, 300 to 359,
400 to 459, 500 to 559,
600 to 659, 700 to 759,
800 to 859, 900 to 959,
0
1000 to 1059, 1100 to 1159,
(00:00)
1200 to 1259,1300 to 1359,
1400 to 1459, 1500 to 1559,
1600 to 1659, 1700 to 1759,
1800 to 1859,1900 to 1959,
2000 to 2059, 2100 to 2159,
2200 to 2259, 2300 to 2359
Description
Set the year.
Set the month and day.
1000's and 100's digits: Month (1 (January) to 12
(December)).
10's and 1's digits: Day (1 to the last day of the
month (28, 29, 30, or 31)).
For December 31, set "1231".
Set the hour and minute using the 24-hour clock.
1000 and 100 digits: 0 to 23 hours
10 and 1 digits: 0 to 59 minutes
For 23:59, set "2359".