Pr.
Name
152
Zero current detection level
153
Zero current detection time
Voltage reduction selection during stall
154
prevention operation
RT signal function validity condition
155
selection
156
Stall prevention operation selection
157
OL signal output timer
158
AM terminal function selection
Automatic switchover frequency range from
159
bypass to inverter operation
160
User group read selection
161
Parameter for manufacturer setting. Do not set.
Automatic restart after instantaneous power
162
failure selection
163
First cushion time for restart
164
First cushion voltage for restart
165
Stall prevention operation level for restart
Output current detection signal retention
166
time
Output current detection operation
167
selection
168
Parameter for manufacturer setting. Do not set.
169
170
Watt-hour meter clear
171
Operation hour meter clear
172
User group registered display/batch clear
173
User group registration
174
User group clear
178
STF terminal function selection
179
STR terminal function selection
180
RL terminal function selection
181
RM terminal function selection
182
RH terminal function selection
183
RT terminal function selection
184
AU terminal function selection
185
JOG terminal function selection
186
CS terminal function selection
187
MRS terminal function selection
188
STOP terminal function selection
189
RES terminal function selection
190
RUN terminal function selection
191
SU terminal function selection
192
IPF terminal function selection
193
OL terminal function selection
194
FU terminal function selection
195
ABC1 terminal function selection
196
ABC2 terminal function selection
232
Multi-speed setting (speed 8)
233
Multi-speed setting (speed 9)
234
Multi-speed setting (speed 10)
235
Multi-speed setting (speed 11)
236
Multi-speed setting (speed 12)
237
Multi-speed setting (speed 13)
238
Multi-speed setting (speed 14)
239
Multi-speed setting (speed 15)
240
Soft-PWM operation selection
241
Analog input display unit switchover
688
APPENDIX
Instruction
code

34 B4 1
35 B5 1
36 B6 1
37 B7 1
38 B8 1
39 B9 1
3A BA 1
3B BB 1
()
00 80 2
02 82 2
03 83 2
04 84 2
05 85 2
06 86 2
07 87 2
0A 8A 2
0B 8B 2
0C 8C 2
0D 8D 2
0E 8E 2
12 92 2
13 93 2
14 94 2
15 95 2
16 96 2
17 97 2
18 98 2
19 99 2
1A 9A 2
1B 9B 2
1C 9C 2
1D 9D 2
1E 9E 2
1F 9F 2
20 A0 2
21 A1 2
22 A2 2
23 A3 2
24 A4 2
28 A8 2
29 A9 2
2A AA 2
2B AB 2
2C AC 2
2D AD 2
2E AE 2
2F AF 2
30 B0 2
31 B1 2
Control method

Vector
Vector
Vector
Sensorless
Sensorless
Sensorless

Parameter
PM
PM
PM

Hide quick links: