 DriveControl writing restriction selection (P.N242)
• The command source to change the DriveControl settings can be restricted to only the command source selected
by Pr.550 NET mode operation command source selection.
Setting value
Pr.349
N010
N240
N241
0
0
0
0
1
1
0
0
100
0
1
0
101
1
1
0
1000
0
0
1
1001
1
0
1
1100
0
1
1
1101
1
1
1
10000
0
0
0
10001
1
0
0
10100
0
1
0
10101
1
1
0
11000
0
0
1
11001
1
0
1
11100
0
1
1
11101
1
1
1
*1
The operation mode affects the availability of communication reset.
*2
The ON/OFF state of the power supply affects the ON/OFF state of Ready bit.
*3
When 24 V external power is available for control circuit or power is input only to control circuit.
*4
Available when the HMS network option is installed.
 Inverter monitor items / command items
• The following inverter monitor items are added.
16-bit data
No.
Torque (positive polarity for driving torque / negative polarity
H0024
for regenerative braking torque)
Communication reset
*1
selection
Other than
N242
NET
NET
operation
operation
mode
mode
Reset
Reset
0
enabled
enabled
Reset
Reset
0
enabled
disabled
Reset
Reset
0
enabled
enabled
Reset
Reset
0
enabled
disabled
Reset
Reset
0
enabled
enabled
Reset
Reset
0
enabled
disabled
Reset
Reset
0
enabled
enabled
Reset
Reset
0
enabled
disabled
Reset
Reset
1
enabled
enabled
Reset
Reset
1
enabled
disabled
Reset
Reset
1
enabled
enabled
Reset
Reset
1
enabled
disabled
Reset
Reset
1
enabled
enabled
Reset
Reset
1
enabled
disabled
Reset
Reset
1
enabled
enabled
Reset
Reset
1
enabled
disabled
Description
Description
Ready bit status selection
Main circuit:
Main circuit:
power-ON
power-OFF
Ready bit:
Ready bit:
ON
ON
Ready bit:
Ready bit:
ON
ON
Ready bit:
Ready bit:
ON
OFF
Ready bit:
Ready bit:
ON
OFF
Ready bit:
Ready bit:
ON
ON
Ready bit:
Ready bit:
ON
ON
Ready bit:
Ready bit:
ON
OFF
Ready bit:
Ready bit:
ON
OFF
Ready bit:
Ready bit:
ON
ON
Ready bit:
Ready bit:
ON
ON
Ready bit:
Ready bit:
ON
OFF
Ready bit:
Ready bit:
ON
OFF
Ready bit:
Ready bit:
ON
ON
Ready bit:
Ready bit:
ON
ON
Ready bit:
Ready bit:
ON
OFF
Ready bit:
Ready bit:
ON
OFF
Unit
0.1%
4
*2
Reset
DriveControl
selection after
writing
inverter faults
restriction
*3
are cleared
selection
Reset enabled
Not restricted
Reset enabled
Not restricted
Reset enabled
Not restricted
Reset enabled
Not restricted
Reset
Not restricted
*4
disabled
Reset
Not restricted
*4
disabled
Reset
Not restricted
*4
disabled
Reset
Not restricted
*4
disabled
Reset enabled
Restricted
Reset enabled
Restricted
Reset enabled
Restricted
Reset enabled
Restricted
Reset
Restricted
*4
disabled
Reset
Restricted
*4
disabled
Reset
Restricted
*4
disabled
Reset
Restricted
*4