4.4.2
JOG operation from the operation panel
POINT
POINT
• Operate only while
Operation example
Operate at 5 Hz.
Screen at power-ON
1.
The monitor display appears.
Changing the operation mode
2.
Press
twice to choose the PUJOG operation mode. [JOG] indicator is on.
Start → acceleration → constant speed
3.
Keep pressing
time, and "5.00 Hz" appears.
Deceleration → stop
4.
Release
or
and the motor stops rotating with "0.00 Hz" displayed.
NOTE
• To change the frequency, change Pr.15 Jog frequency (initial value "5 Hz").
• To change the acceleration/deceleration time, change Pr.16 Jog acceleration/deceleration time (initial value "0.5 s").
Parameters referred to
Pr.15 Jog frequency
page 312
Pr.16 Jog acceleration/deceleration time
or
is pressed.
Operation panel
Operation
or
. The frequency value on the indication increases in Pr.16 Jog acceleration/deceleration
. The frequency value on the indication decreases in Pr.16 Jog acceleration/deceleration time,
page 312