Mitsubishi Electric 800 Series Instruction Manual page 98

600v class specification inverter
Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

Pr.
Pr.
group
Stall prevention operation level
22
H500
(Torque limit level)
Stall prevention operation level
23
H610
compensation factor at double
speed
D304
24 to
Multi-speed setting (4 speed to 7
to
speed)
27
D307
Multi-speed input compensation
28
D300
selection
Acceleration/deceleration pattern
29
F100
selection
30
E300
Regenerative function selection
31
H420
Frequency jump 1A
32
H421
Frequency jump 1B
33
H422
Frequency jump 2A
34
H423
Frequency jump 2B
35
H424
Frequency jump 3A
36
H425
Frequency jump 3B
37
M000
Speed display
41
M441
Up-to-frequency sensitivity
42
M442
Output frequency detection
Output frequency detection for
43
M443
reverse rotation
Second acceleration/deceleration
44
F020
time
45
F021
Second deceleration time
46
G010
Second torque boost
47
G011
Second V/F (base frequency)
Second stall prevention operation
48
H600
level
Second stall prevention operation
49
H601
frequency
50
M444
Second output frequency detection
H010
Second electronic thermal O/L relay
51
Rated second motor current
C203
Operation panel main monitor
52
M100
selection
54
M300
FM terminal function selection
55
M040
Frequency monitoring reference
56
M041
Current monitoring reference
57
A702
Restart coasting time
58
A703
Restart cushion time
Name
Setting range
0 to 400%
0 to 200%, 9999
0 to 590 Hz, 9999
0, 1
0 to 6
0 to 2, 10, 11, 20, 21,
100 to 102, 110, 111,
120, 121
2, 10, 11, 102, 110,
111

0 to 590 Hz, 9999
0 to 590 Hz, 9999
0 to 590 Hz, 9999
0 to 590 Hz, 9999
0 to 590 Hz, 9999
0 to 590 Hz, 9999
0, 1 to 9998
0 to 100%
0 to 590 Hz
0 to 590 Hz, 9999
0 to 3600 s
0 to 3600 s, 9999
0 to 30%, 9999
0 to 590 Hz, 9999
0 to 400%
0 to 590 Hz, 9999
0 to 590 Hz
0 to 500 A, 9999
0 to 3600 A, 9999
0, 5 to 14, 17 to 20,
22 to 36, 38 to 46,
50 to 57, 61, 62, 64,
67, 71 to 75, 87 to 98,
100
1 to 3, 5 to 14, 17, 18,
21, 24, 32 to 34, 36,
46, 50, 52, 53, 61, 62,
67, 70, 87 to 90, 92,
93, 95, 97, 98
0 to 590 Hz
0 to 500 A
0 to 3600 A
0, 0.1 to 30 s, 9999
0 to 60 s
Parameter list (by parameter number)
Minimum
setting
Initial value
increments
0.1%
150%
0.1%
9999
0.01 Hz
9999
1
0
1
0
1
0

1
10
0.01 Hz
9999
0.01 Hz
9999
0.01 Hz
9999
0.01 Hz
9999
0.01 Hz
9999
0.01 Hz
9999
1
0
0.1%
10%
0.01 Hz
6 Hz
0.01 Hz
9999
0.1 s
5 s
0.1 s
9999
0.1%
9999
0.01 Hz
9999
0.1%
150%
0.01 Hz
0 Hz
0.01 Hz
30 Hz
0.01 A

9999
0.1 A

1
0
1
1
0.01 Hz
60 Hz
0.01 A


Inverter rated
current
0.1 A


0.1 s
9999
0.1 s
1 s
PARAMETERS
Parameter List
Refer
to
page
154,
Pr.
332
List
332
314
314
274
608
330
330
330
330
330
330
345
379
379
379
269,
508
269,
508
589
591
332
332
379
317,
426,
436
5
347
357
357
357
515
515
97

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents