Mitsubishi Electric 800 Series Instruction Manual page 350

600v class specification inverter
Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

Increment
Monitor item
and unit
Orientation
1
status

Actual operation
1 h
time

Motor load factor
0.1%
0.01 kWh/
Cumulative power
0.1 kWh

Position command
1
Position command
1
(upper digits)
Current position
1
Current position
1
(upper digits)
Droop pulse
1
Droop pulse (upper
1
digits)
Torque command
0.1%
Torque current
0.1%
command
0.01 kW/0.1
Motor output
kW

Feedback pulse

Torque monitor
(power driving/
0.1%
regenerative driving
polarity switching)
Trace status
1
SSCNET III
communication
1
status

Pr. setting
RS-485
22
H16
23
H17
24
H18
25
H19
26
H1A
27
H1B
28
H1C
29
H1D
30
H1E
31
H1F
32
H20
33
H21
34
H22
35
H23
36
H24
38
H26
39
H27
(M) Monitor display and monitor output signal
Negative
MODBUS
indication
RTU
(-)

Displays values only when orientation
control is enabled. (Displays the
40222
voltage monitor when a vector control
compatible option is not connected.)
(Refer to
Displays the cumulative time since
the inverter began running.
The number of times the monitor
40223
value exceeded 65535 h can be
checked with Pr.564
This can be cleared with Pr.171.
(Refer to
Displays the output current value as a
percentage, considering the inverter
rated current value as 100%.
40224
Monitor value = output current
monitor value / inverter rated current
 100 [%]
Displays the cumulative energy
based on the output power monitor.
40225
This can be cleared with Pr.170.
(Refer to
40226
Displays the position command
(decimal) before the electronic gear is
40227
set.
40228
Displays the value of the position
feedback pulse after converting it into
the number of pulses before the
40229
electronic gear is set.
40230
Displays the droop pulse before the
electronic gear.
40231
Displays the torque command value
40232
obtained from the vector control
results.
Displays the commanded current for
40233
the torque.
Multiplies the output torque at that
time with the motor speed, and
40234
displays the machine output for the
motor shaft end.
Display the number of pulses fed
back from the encoder during one
sampling (also displays during stop).
(Displays the voltage monitor when a
vector control compatible option is not
connected.)
40235
The sampling time varies with the
Pr.369 Number of encoder pulses
setting.
1050 or less: 1 s
1051 to 2100: 0.5 s
2101 to 4096: 0.25 s
Displays the same value as that of
the motor torque. Displays plus value
40236
for power driving and negative value
for regenerative driving.
Displays the trace status. (Refer to
40238
page
The SSCNET III communication
status between the inverter and the
40239
controller is displayed.
The output voltage is displayed when
the FR-A8NS is not installed.
Description
page
473)
page
354)
page
353.)



533).
349
PARAMETERS
5
GROUP
M