(F) Setting of acceleration/deceleration time and acceleration/deceleration pattern
Parameters referred to
???????
Pr.3 Base frequency
page 591
Pr.10 DC injection brake operation frequency
Pr.29 Acceleration/deceleration pattern selection
Pr.125, Pr.126 (frequency setting gain frequency)
Pr.178 to Pr.182 (Input terminal function selection)
Pr.264 Power-failure deceleration time 1, Pr.265 Power-failure deceleration time 2
5.8.2

Acceleration/deceleration pattern

The acceleration/deceleration pattern can be set according to the application.
In addition, the backlash measures that stop acceleration/deceleration by the frequency or time set with parameters at
acceleration/deceleration can be set.
Pr.
29
Acceleration/deceleration pattern
F100
selection
140
Backlash acceleration stopping
F200
frequency
141
Backlash acceleration stopping time
F201
142
Backlash deceleration stopping
F202
frequency
143
Backlash deceleration stopping time
F203
380
Acceleration S-pattern 1
F300
381
Deceleration S-pattern 1
F301
382
Acceleration S-pattern 2
F302
383
Deceleration S-pattern 2
F303
516
S-pattern time at a start of
F400
acceleration
517
S-pattern time at a completion of
F401
acceleration
518
S-pattern time at a start of
F402
deceleration
519
S-pattern time at a completion of
F403
deceleration
Linear acceleration/deceleration (Pr.29 = "0" initial value)
• When the frequency is changed for acceleration, deceleration, etc. during inverter operation, the output frequency is
changed linearly (linear acceleration/deceleration) to reach the set frequency without straining the motor and inverter.
Linear acceleration/deceleration has a uniform frequency/time slope.
Setting value "0"
[Linear acceleration
/ deceleration]
Time
274
PARAMETERS
page 599
page 274
page 402
page 415
Name
Initial value Setting range
0
1 Hz
0.5 s
1 Hz
0.5 s
0
0
0
0
0.1 s
0.1 s
0.1 s
0.1 s
page 526
0
Linear acceleration/deceleration
1
S-pattern acceleration/deceleration A
2
S-pattern acceleration/deceleration B
3
Backlash measures
4
S-pattern acceleration/deceleration C
5
S-pattern acceleration/deceleration D
6
Variable-torque acceleration/deceleration
0 to 590 Hz
0 to 360 s
Set the stopping frequency and time during
backlash measures.
Valid by backlash measures (Pr.29="3").
0 to 590 Hz
0 to 360 s
0 to 50%
Set the time for drawing the S-pattern from
acceleration/deceleration start to linear
acceleration as a ratio (%) of acceleration/
0 to 50%
deceleration time (Pr.7, 8, etc.).
The acceleration/deceleration curve can be
0 to 50%
switched by the X20 signal.
Valid by S-pattern acceleration/deceleration
C (Pr.29="4").
0 to 50%
0.1 to 2.5 s
Set the time required for acceleration (S-
0.1 to 2.5 s
pattern) of S-pattern acceleration/
deceleration.
Valid by S-pattern acceleration/deceleration
0.1 to 2.5 s
D (Pr.29="5").
0.1 to 2.5 s
Description