Mitsubishi Electric 800 Series Instruction Manual page 303

600v class specification inverter
Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

(D) Operation command and frequency command
Selection of the command source of the PU operation mode (Pr.551)
• Any of the PU connector, RS-485 terminals, or USB connector can be specified as the command source in the PU
operation mode.
• Set Pr.551="1" to use communication connected to the RS-485 terminals to write parameters or execute start and
frequency commands in the PU operation mode. Set Pr.551="3" or "9999" to use the USB connector.
NOTE
• When Pr.550 ="1" (NET mode RS-485 terminals) and Pr.551 ="1" (PU mode RS-485 terminals), the PU operation mode has
a precedence. For this reason, if the communication option is not mounted, switching to the Network operation mode is not
longer possible.
• Changed setting values are enabled at power-ON or inverter reset.
Pr.550
Pr.551
setting
setting
PU connector
1
2
PU operation mode
0
3
9999
PU operation
(initial
mode
value)
1
2
PU operation mode
1
3
9999
PU operation
(initial
mode
value)
1
2
PU operation mode
9999
(initial
value)
3
9999
PU operation
(initial
mode
value)

The MODBUS RTU protocol cannot be used in the PU operation mode. To use the MODBUS RTU protocol, set Pr.551="2".

If the communication option is not mounted, switching to the Network operation mode is not longer possible.

When Pr.551= "9999", the priority of the PU command source is USB connector > PU connector.
302
PARAMETERS
Command source
USB connector
PU operation mode
PU operation
mode


PU operation mode
PU operation
mode


PU operation mode
PU operation
mode


RS-485
Communication
terminals
option
PU operation
NET operation
mode
mode


NET operation
mode

NET operation
mode

NET operation
mode

PU operation
mode

NET operation
mode
NET operation
mode
NET operation
mode
PU operation
NET operation
mode
mode


NET operation
mode

NET operation
mode
NET operation
mode

NET operation
mode
NET operation
mode

NET operation
mode
REMARKS
Switching to NET
operation mode disabled
With communication
option
Without communication
option
With communication
option
Without communication
option
With communication
option
Without communication
option

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents